ATX X-Ray Equine Station

The Equine X-ray Station is comprised of:

  • ATX Smart portable long life battery powered X-ray generator (ATX EPX-F1600 1.6kW 90KV/30MA) View here
  • Ultra-140V DR (14x17inch / Wireless / CSI ) View here
  • Tough Book or GETAC laptop
  • ATX acrylic hard DR protector
  • DR carry bag
  • One year trial of iTX Cloud PACS, EzyVet Integration available View here,
  • Compliance testing as per local radiation health regulations.

Optional accessories:

  • Lead gown start up package (1 lead gown, 1 thyroid collar, 1 pair of vet mitts).
  • Premium Extended warranty for DR detectors. Includes DR regular maintenance, unlimited remote support and hot swap units in case of breakdown (DR &PC) plus 25% discount on service visits
  • Podoblocks: podo-prot.box or cowboybox this unique system guarantees maximum radiation distance and no fingers on the x-raysView here
  • Protective charging transport case, able to content the X-Ray unit, DR, PC and charger.
  • DR hard protector & stand-off kit:  the DR panel protective case & stand-off kit has been designed to protect your x-ray DR panel out on the field.
    the stand-off arm can be used to distance the operator from the initial X-Ray beam & animal where possible. This protective case fits a 14×17 inch DR panel & will provide 1 meters distance when using the stand-off arm. View here
  • Equine tunnel- heavy duty: the ATX DR protective tunnel is a protector that can be used to perform X-Ray studies of equine extremities eliminating potential damage that can occur.  This unit is  constructed to protect a 35x43cm (14x17inch) DR or CR panel. It has 6 rubber feet to ensure a strong footing and provide grip to all surfaces & terrain. (current pictures does not include this feature). View here
  • Acrylic hard DR protector- Podoblock

ATX Manual Portable X-ray Generator

Model ATXHF16 ATXHF24 ATXHF28 ATXHF32 ATXHF40 ATXHF50
Description 1.6kW 100kHz Portable X-Ray 2.4kW 50kHz Portable X-Ray 2.8kW 50kHz Portable X-Ray 3.2kW 60kHz Portable X-Ray 4.0kW 60kHz Portable X-Ray 5.1kW 60kHz Portable X-Ray
Features A lightweight high mA system.  Large animal and equine specialist choice. Fine focal spot High kV system.  Ideal for Thorax imaging High frequency general radiography system. Ability to take very short exposures limiting unwanted digital noise to improve image quality. Highest power portable available.
Benefits Easy to handle and with very high frequency for safer use.
Ideal for yearling sales studies.
High quality, small focal spot xray tube for fine grain images.
Excellent dose reproducibility resilient to input power fluctuations
High frequency invertor for better efficiency and safety.
Prolonged lifetime of xray tube
Plugs into ordinary power outlets.
Powerful output for a wide range of radiographic techniques
High quality, small focal spot xray tube for fine grain images.
Excellent dose reproducibility Resilient to input power fluctuations
Plugs into ordinary power outlets.
Powerful output for a wide range of radiographic techniques
High quality, small focal spot xray tube for fine grain images.
Excellent dose reproducibility Resilient to input power fluctuations
Prolonged lifetime of xray tube
Plugs into ordinary power outlets.
Powerful 4.0kW high mA short exposures.
Ideal for DR or CR acquisition systems.
High quality, small focal spot xray tube for fine grain images.
Powerful 5.0kW high mA short exposures.
Ideal for DR or CR acquisition systems.
High quality, small focal spot xray tube for fine grain images.
Image .
Anatomical Preset Settings 6 6 6 6 6 6
Weight  (kg) 6.8 11 11 12 12 12
mAs/kV Range  0.4mAs-100mAs, 40kV-90kV (30mA Max) 0.4mAs-100mAs, 40kV-100kV (40mA Max) 0.4mAs-100mAs, 40kV-120kV (40mA Max) 0.4mAs-100mAs, 40kV-100kV (60mA Max) 0.4mAs-100mAs, 40kV-110kV (80mA Max) 0.4mAs-200mAs, 40kV-120kV (100mA Max)
Tube Focal Spot  1.2mm 1.2mm 1.2mm 2.0mm 1.8mm 1.8mm
Collimator Manually adjustable, full field light beam Manually adjustable, full field light beam Manually adjustable, full field light beam Manually adjustable, full field light beam Manually adjustable, full field light beam Manually adjustable, full field light beam
Collimator Lamp  50W/12V + Laser 50W/12V + Laser 100W/12V + Laser 100W/12V + Laser 50W/12V + Laser 50W/12V + Laser
Collimator Remote Prep switch touch Prep switch touch Prep switch touch Prep switch touch Prep switch touch Prep switch touch
SID Scale Length  2M 2M 2M 2M 2M 2M
Line Power  230V, 50 or 60 Hz  230V, 50 or 60 Hz  230V, 50 or 60 Hz  230V, 50 or 60 Hz  230V, 50 or 60 Hz  230V, 50 or 60 Hz
Phase  Single Phase  Single Phase  Single Phase  Single Phase Single Phase Single Phase
Approx Dimensions 335 x153 x 330mm 360(W) x 200(D) x 190(H) mm 360(W) x 200(D) x 190(H) mm 360(W) x 200(D) x 190(H) mm 360(W) x 200(D) x 190(H) mm 360(W) x 200(D) x 190(H) mm
System Diagnositic Self-detection of error condition Self-detection of error condition Self-detection of error condition Self-detection of error condition Self-detection of error condition Self-detection of error condition

Podoblock. 90

Podoblock. 90
Aluminium.
Incl. 1 Topblock.
4 Rubber Feet.
LM / AP / 45º Hands- free system.

In combination with the Podoholder, Podo-Prot.box or Cowboybox this unique system guarantees maximum radiation distance and no fingers on the X-rays.

Podoblock. 120

Podoblock. 120
Aluminium.
Incl. 1 Topblock.
4 Rubber Feet.
LM / AP / 45º Hands- free system.
n combination with our Podoholder, Podo-Prot.box or Cowboybox this unique system guarantees maximum radiation distance and no fingers on the X-rays.
The height from ground to tip off hoof in Podoblock 120 mm

Podoblock. 170

Podoblock. 170
Aluminium.
Incl. 1 Topblock.
4 Rubber Feet.
LM / AP / 45º Hands- free system.
n combination with our Podoholder, Podo-Prot.box or Cowboybox this unique system guarantees maximum radiation distance and no fingers on the X-rays.
The height from ground to tip off hoof in Podoblock 170 mm

Raymaster Full Spine Integrated Digital X-Ray Chiropractic Solution

Raymaster Full Spine Integrated Digital X-Ray Chiropractic solution is comprised of:

  • VS100 Wall stand. View here
  • FWFC Tube Stand. View here
  • CMP200 Generator View here
  • Varex Rad14 X-ray tube. View here
  • Longtail DR  with Remote control electric stand View here
  • One year trial of iTX Cloud PACS, for Viewing and Distribution of studies in DICOM format View here,
  • Pre-installation project management and regulatory compliance assistance as required·
  • Compliance testing as per local radiation health regulations.
  • 2 years standard warranty

Optional Additional Benefits

  • Premium Extended warranty for DR detectors. Includes DR regular maintenance, unlimited remote support and hot swap units in case of breakdown (DR &PC) plus 25% discount on service visits
  • Nolan Filters – Collimator Filters. The two significant benefits of these filters are to enable spinal studies to be completed with the lowest possible x-ray dose while improving the image quality.  View here

Raymaster Integrated Digital X-Ray Chiropractic Solution

Raymaster Integrated Digital X-Ray Chiropractic solution is comprised of:

  • VS100 Wall stand. View here
  • FWFC Tube Stand. View here
  • CMP200 Generator View here
  • Varex Rad14 X-ray tube. View here
  • Ultra-140H DR or Ultra 99DR  (any variation) View here
  • Lenovo ThinkCentre M920z All-in-One Computer – Core i5 i5-8500 – 8 GB RAM – 512 GB SSD – 60.5 cm (23.8″) 1920 x 1080 – Desktop
  • One year trial of iTX Cloud PACS, for Viewing and Distribution of studies in DICOM format View here,
  • Pre-installation project management and regulatory compliance assistance as required·
  • Compliance testing as per local radiation health regulations.
  • Initial 2 years standard warranty

Optional Additional Benefits

  • Premium Extended warranty for DR detectors. Includes DR regular maintenance, unlimited remote support and hot swap units in case of breakdown (DR &PC) plus 25% discount on service visits
  • Nolan Filters – Collimator Filters. The two significant benefits of these filters are to enable spinal studies to be completed with the lowest possible x-ray dose while improving the image quality. View here